China Echelle Grating Manufacturer

This grating features low line density and a high blaze angle, utilizing high diffraction orders (tens to hundreds) to achieve extremely high chromatic dispersion and resolution.

 

Key Advantages

• Extremely high resolution: By utilizing high diffraction orders, the resolution far exceeds that of conventional gratings

• Large blaze angle: Typically above 60°, featuring a stepped groove profile

• Two-dimensional spectroscopy capability: When combined with prism cross-dispersion, full-spectrum instantaneous acquisition can be achieved

 

Typical Applications

ICP-MS, astronomical spectrometers, LIBS, and high-resolution laser spectroscopy

productcate-750-750
 
Number Line density (l/mm)

Blaze angle

Scribing area (H×W, mm²)

JY3-001

54.5

46°

25×25 & 50×50

JY3-002

79

63.43°

25×25 & 50×50

JY3-003

80

63.43°

25×25 & 50×50

Other specifications will be added gradually.
 
  • Echelle Grating 79l/mm
    For applications demanding the highest spectral resolution—where precision spectroscopy, astronomical observation, and advanced analytical instrumentation converge—standard diffraction gratings often
  • Echelle Grating 54.5l/mm
    a high-dispersion optical element engineered for demanding analytical applications. Designed with a 46° nominal blaze angle, this grating delivers exceptional efficiency in high-order diffraction,
 
Echelle Grating 54.5l/mm

 

High-Order Diffraction Gratings for High-Resolution Spectroscopy

Echelle gratings are reflection diffraction gratings operated at relatively high diffraction orders and high blaze angles. This advanced optical configuration enables a spectrograph to achieve exceptional spectral dispersion and high resolution within a compact optical system.
For OEM spectrometer manufacturers and research instruments, an echelle grating must be specified as an integral part of the complete optical design rather than selected by groove density alone. Groove spacing, blaze geometry, operating wavelength, diffraction order, optical coating, clear aperture, and incidence configuration all dictate final system performance.

 

Product Overview and Working Principle
 

An echelle grating is engineered for high-resolution spectrographs where conventional diffraction gratings cannot provide the required resolving power within the available optical path.

High-Order Operation

Concentrates useful diffracted energy around the designed blaze condition at high diffraction orders.

Cross-Dispersion

Because multiple diffraction orders overlap in the same wavelength region, echelle spectrographs utilize a cross-dispersing optical element to spatially separate adjacent orders on the detector.

Broad Range & High Resolution

Ideal for instruments requiring the resolution of closely spaced spectral lines across a broad wavelength range.

 

Typical Characteristics

 

 

High diffraction order operation (typically orders 20 to over 100)
High blaze angle geometry
High spectral dispersion and resolving power (R = λ / Δλ)
Compatibility with cross-dispersed spectrograph architectures
Strict compliance with ISO 9001 quality management standards for OEM integration

 

 

Why Select an Echelle Grating?

The primary driver for choosing an echelle grating is the requirement for high spectral resolution. While a conventional grating might demand a much larger illuminated area or an extended optical path to reach similar resolving power, an echelle configuration leverages steep blaze angles and high diffraction orders to pack strong angular dispersion into a compact footprint.
However, an echelle grating is not automatically the correct choice for every spectrometer. High-order operation inherently introduces order overlap, requiring a well-designed cross-disperser and proper detector management.

Echelle Grating 79l/mm

 

 
Echelle Grating Selection Guide
 

Selecting an echelle grating requires a systematic evaluation of optical parameters:

01/

Define the Operating Wavelength Range: Specify central, minimum, and maximum wavelengths, required spectral bandwidth, and primary analytical lines. A grating optimized for one spectral region cannot be assumed to deliver equal efficiency in another.

02/

Determine Spectral Resolution Requirements: Express resolution via absolute wavelength resolution (Δλ) or resolving power (R = λ / Δλ). Evaluate the grating alongside spectrograph optics, slit width, and detector pixel size.

03/

Groove Density and Groove Spacing: Groove density works in tandem with blaze angle, operating order, and angle of incidence. Never specify groove density in isolation.

04/

Blaze Angle and Blaze Wavelength: Determines how diffracted energy is preferentially concentrated. Specify Littrow or non-Littrow configurations where applicable.

 

Technical Specifications for Procurement

 

 

When preparing a Technical Specification Sheet or Request for Quotation (RFQ), include the following standardized parameters: 

 

Parameter

Procurement Requirement / Specification

Grating Type

Echelle reflection diffraction grating

Groove Density

Specify required grooves/mm

Blaze Angle

Specify required or calculated value

Blaze Wavelength

Specify design wavelength

Diffraction Order

Specify target operating order

Wavelength Range

Define working spectral range

Substrate Material

Specify material (e.g., Zerodur, fused silica) and dimensional requirements

Optical Coating

Specify coating type (e.g., UV-enhanced aluminum, gold) and wavelength range

Clear Aperture

Define illuminated optical aperture

Overall Dimensions

Match spectrograph mounting envelope

Surface Quality

Specify grade (e.g., scratch-dig)

Surface Flatness

Specify according to optical system requirements (e.g., λ / 10 at 633 nm)

Wavefront Quality

Specify where system-level performance requires it

Efficiency

Define target wavelength and measurement condition

Damage Threshold

Required for high-power laser and industrial optical systems

 

Manufacturing Considerations, Quality Control & OEM Customization

Achieving superior optical performance requires strict manufacturing tolerances beyond nominal groove counts:


Groove Profile & Blaze Control

Precise shaping ensures maximum energy distribution into the intended high diffraction order with minimal scatter.


Substrate Stability

Substrate selection must account for thermal environment, mechanical integration, and optical surface deformation.

Coating Performance

Reflective coatings are tailored to specific spectral bands to maximize efficiency and minimize absorption losses.

Surface Flatness & Finish

Controlled quantitatively to reduce stray light and wavefront errors in precision analytical instruments.

OEM Customization & Scalability

We support flexible custom engineering—including non-standard dimensions, specialized blaze angles, and custom substrate configurations—backed by robust volume manufacturing capabilities to meet seamless OEM integration schedules.

 

Typical Applications & Real-World Use Cases

 

High-Resolution Spectrometers

Resolving closely spaced spectral features in analytical chemistry and material testing (e.g., ICP-OES elemental analysis).

01

Echelle Spectrographs

Serving as the primary dispersive element in cross-dispersed configurations for simultaneous wide spectral coverage and ultra-high resolution.

02

Astronomical Spectroscopy

Distinguishing narrow spectral lines from stellar and galactic sources in ground- and space-based telescopes.

03

Atomic & Emission Spectroscopy

Analyzing closely spaced atomic emission lines with high precision for environmental and industrial monitoring.

04

Research Spectroscopy

Tailored for custom experimental setups requiring specialized coatings and blaze geometries.

05

 

FAQ

 

Q: What is an echelle grating?

A: An echelle grating is a specialized reflection diffraction grating designed to operate at high diffraction orders and high blaze angles, primarily used to achieve high spectral resolution in compact optical layouts.

Q: Why does an echelle spectrograph require a cross-disperser?

A: High-order operation causes multiple diffraction orders to overlap spatially in wavelength. A cross-disperser separates these orders orthogonally, allowing a 2D detector to record them as distinct spectral traces without ambiguity.

Q: Is groove density the most critical parameter?

A: No. While groove density matters, blaze angle, blaze geometry, diffraction order, substrate quality, and optical coatings collectively dictate system-level performance.

As one of the leading echelle grating manufacturers and suppliers in China, we offer a wide range of products with superior quality. Please feel free to wholesale customized echelle grating from our factory. Welcome to view our website for more information.

High Resolution Diffraction Grating, Blazed Echelle Grating, Echelle Grating 79l mm
Send Inquiry