China Echelle Grating Manufacturer
This grating features low line density and a high blaze angle, utilizing high diffraction orders (tens to hundreds) to achieve extremely high chromatic dispersion and resolution.
Key Advantages
• Extremely high resolution: By utilizing high diffraction orders, the resolution far exceeds that of conventional gratings
• Large blaze angle: Typically above 60°, featuring a stepped groove profile
• Two-dimensional spectroscopy capability: When combined with prism cross-dispersion, full-spectrum instantaneous acquisition can be achieved
Typical Applications
ICP-MS, astronomical spectrometers, LIBS, and high-resolution laser spectroscopy

| Number | Line density (l/mm) |
Blaze angle |
Scribing area (H×W, mm²) |
|
JY3-001 |
54.5 |
46° |
25×25 & 50×50 |
|
JY3-002 |
79 |
63.43° |
25×25 & 50×50 |
|
JY3-003 |
80 |
63.43° |
25×25 & 50×50 |
| Other specifications will be added gradually. | |||
-
Echelle Grating 79l/mmFor applications demanding the highest spectral resolution—where precision spectroscopy, astronomical observation, and advanced analytical instrumentation converge—standard diffraction gratings often
-
Echelle Grating 54.5l/mma high-dispersion optical element engineered for demanding analytical applications. Designed with a 46° nominal blaze angle, this grating delivers exceptional efficiency in high-order diffraction,

Echelle gratings are reflection diffraction gratings operated at relatively high diffraction orders and high blaze angles. This advanced optical configuration enables a spectrograph to achieve exceptional spectral dispersion and high resolution within a compact optical system.
For OEM spectrometer manufacturers and research instruments, an echelle grating must be specified as an integral part of the complete optical design rather than selected by groove density alone. Groove spacing, blaze geometry, operating wavelength, diffraction order, optical coating, clear aperture, and incidence configuration all dictate final system performance.
Product Overview and Working Principle
An echelle grating is engineered for high-resolution spectrographs where conventional diffraction gratings cannot provide the required resolving power within the available optical path.
High-Order Operation
Concentrates useful diffracted energy around the designed blaze condition at high diffraction orders.
Cross-Dispersion
Because multiple diffraction orders overlap in the same wavelength region, echelle spectrographs utilize a cross-dispersing optical element to spatially separate adjacent orders on the detector.
Broad Range & High Resolution
Ideal for instruments requiring the resolution of closely spaced spectral lines across a broad wavelength range.
Typical Characteristics
High diffraction order operation (typically orders 20 to over 100)
High blaze angle geometry
High spectral dispersion and resolving power (R = λ / Δλ)
Compatibility with cross-dispersed spectrograph architectures
Strict compliance with ISO 9001 quality management standards for OEM integration
The primary driver for choosing an echelle grating is the requirement for high spectral resolution. While a conventional grating might demand a much larger illuminated area or an extended optical path to reach similar resolving power, an echelle configuration leverages steep blaze angles and high diffraction orders to pack strong angular dispersion into a compact footprint.
However, an echelle grating is not automatically the correct choice for every spectrometer. High-order operation inherently introduces order overlap, requiring a well-designed cross-disperser and proper detector management.

Echelle Grating Selection Guide
Selecting an echelle grating requires a systematic evaluation of optical parameters:
Define the Operating Wavelength Range: Specify central, minimum, and maximum wavelengths, required spectral bandwidth, and primary analytical lines. A grating optimized for one spectral region cannot be assumed to deliver equal efficiency in another.
Determine Spectral Resolution Requirements: Express resolution via absolute wavelength resolution (Δλ) or resolving power (R = λ / Δλ). Evaluate the grating alongside spectrograph optics, slit width, and detector pixel size.
Groove Density and Groove Spacing: Groove density works in tandem with blaze angle, operating order, and angle of incidence. Never specify groove density in isolation.
Blaze Angle and Blaze Wavelength: Determines how diffracted energy is preferentially concentrated. Specify Littrow or non-Littrow configurations where applicable.
Technical Specifications for Procurement
When preparing a Technical Specification Sheet or Request for Quotation (RFQ), include the following standardized parameters:
|
Parameter |
Procurement Requirement / Specification |
|
Grating Type |
Echelle reflection diffraction grating |
|
Groove Density |
Specify required grooves/mm |
|
Blaze Angle |
Specify required or calculated value |
|
Blaze Wavelength |
Specify design wavelength |
|
Diffraction Order |
Specify target operating order |
|
Wavelength Range |
Define working spectral range |
|
Substrate Material |
Specify material (e.g., Zerodur, fused silica) and dimensional requirements |
|
Optical Coating |
Specify coating type (e.g., UV-enhanced aluminum, gold) and wavelength range |
|
Clear Aperture |
Define illuminated optical aperture |
|
Overall Dimensions |
Match spectrograph mounting envelope |
|
Surface Quality |
Specify grade (e.g., scratch-dig) |
|
Surface Flatness |
Specify according to optical system requirements (e.g., λ / 10 at 633 nm) |
|
Wavefront Quality |
Specify where system-level performance requires it |
|
Efficiency |
Define target wavelength and measurement condition |
|
Damage Threshold |
Required for high-power laser and industrial optical systems |
Achieving superior optical performance requires strict manufacturing tolerances beyond nominal groove counts:
Groove Profile & Blaze Control
Precise shaping ensures maximum energy distribution into the intended high diffraction order with minimal scatter.
Substrate Stability
Substrate selection must account for thermal environment, mechanical integration, and optical surface deformation.
Coating Performance
Reflective coatings are tailored to specific spectral bands to maximize efficiency and minimize absorption losses.
Surface Flatness & Finish
Controlled quantitatively to reduce stray light and wavefront errors in precision analytical instruments.
OEM Customization & Scalability
We support flexible custom engineering—including non-standard dimensions, specialized blaze angles, and custom substrate configurations—backed by robust volume manufacturing capabilities to meet seamless OEM integration schedules.
Typical Applications & Real-World Use Cases
High-Resolution Spectrometers
Resolving closely spaced spectral features in analytical chemistry and material testing (e.g., ICP-OES elemental analysis).
01
Echelle Spectrographs
Serving as the primary dispersive element in cross-dispersed configurations for simultaneous wide spectral coverage and ultra-high resolution.
02
Astronomical Spectroscopy
Distinguishing narrow spectral lines from stellar and galactic sources in ground- and space-based telescopes.
03
Atomic & Emission Spectroscopy
Analyzing closely spaced atomic emission lines with high precision for environmental and industrial monitoring.
04
Research Spectroscopy
Tailored for custom experimental setups requiring specialized coatings and blaze geometries.
05
As one of the leading echelle grating manufacturers and suppliers in China, we offer a wide range of products with superior quality. Please feel free to wholesale customized echelle grating from our factory. Welcome to view our website for more information.
High Resolution Diffraction Grating, Blazed Echelle Grating, Echelle Grating 79l mm